William P. Bahnfleth
William P. Bahnfleth
Professor of Architectural Engineering
Geverifieerd e-mailadres voor psu.edu
Titel
Geciteerd door
Geciteerd door
Jaar
Mathematical modeling of ultraviolet germicidal irradiation for air disinfection
WJ Kowalski, WP Bahnfleth, DL Witham, BF Severin, TS Whittam
Quantitative microbiology 2 (3), 249-270, 2000
1692000
Airborne respiratory diseases and mechanical systems for control of microbes
WJ Kowalski, WP Bahnfleth
HPAC Heating, Piping, Air Conditioning 70 (7), 1998
1251998
Energy conservation benefits of a dedicated outdoor air system with parallel sensible cooling by ceiling radiant panels.
JW Jeong, S Mumma, WP Bahnfleth
ASHRAE Transactions 109 (2), 627-636, 2003
1132003
Filtration of airborne microorganisms: modeling and prediction
WJ Kowalski, WP Bahnfleth, TS Whittam
ASHRAE TRANS 105, 4-17, 1999
1051999
Bactericidal effects of high airborne ozone concentrations on Escherichia coli and Staphylococcus aureus
WJ Kowalski, WP Bahnfleth, TS Whittam
Taylor & Francis Group 20 (3), 205-221, 1998
1011998
Resuspension of allergen-containing particles under mechanical and aerodynamic disturbances from human walking
C Gomes, J Freihaut, W Bahnfleth
Atmospheric Environment 41 (25), 5257-5270, 2007
922007
UVGI design basics for air and surface disinfection
WJ Kowalski, WP Bahnfleth
HPAC Heating, Piping, Air Conditioning 72 (1), 2000
692000
Effective UVGI system design through improved modeling
WJ Kowalski, WP Bahnfleth
ASHRAE transactions 106, 721, 2000
692000
Thermal performance of a full-scale stratified chilled-water thermal storage tank
WP Bahnfleth, A Musser
ASHRAE transactions 104, 377, 1998
581998
Evolution of temperature distributions in a full-scale stratified chilled-water storage tank with radial diffusers
A Musser, WP Bahnfleth
ASHRAE Transactions 104, 55, 1998
581998
Constant flow rate charging characteristics of a full-scale stratified chilled water storage tank with double-ring slotted pipe diffusers
WP Bahnfleth, J Song
Applied thermal engineering 25 (17-18), 3067-3082, 2005
572005
Three-dimensional numerical study of slab-on-grade heat transfer
WP Bahnfleth, CO Pedersen
ASHRAE Transactions, 61-72, 1990
561990
Three-dimensional modelling of heat transfer from slab floors
WP Bahnfleth
CONSTRUCTION ENGINEERING RESEARCH LAB (ARMY) CHAMPAIGN IL, 1989
551989
of Variable and Constant Primary-Flow Chilled-Water-Plant Performance
WP Bahnfleth
HPAC Engineering, 2001
542001
MERV filter models for aerobiological applications
WJ Kowalski, WP Bahnfleth
Air Media, Summer 1, 2002
442002
Modeling immune building systems for bioterrorism defense
W Kowalski, W Bahnfleth, A Musser
Journal of Architectural Engineering 9 (2), 86-96, 2003
432003
Demonstration of a Hermetic Airborne Ozone Disinfection System: Studies on E. coli
WJ Kowalski, WP Bahnfleth, BA Striebig, TS Whittam
AIHA Journal 64 (2), 222-227, 2003
432003
Energy Use and Economic Comparison of Chilled-Water Pumping System Alternatives.
WP Bahnfleth, EB Peyer
ASHRAE transactions 112 (2), 2006
372006
Parametric study of charging inlet diffuser performance in stratified chilled water storage tanks with radial diffusers: Part 1–model development and validation
A Musser, WP Bahnfleth
HVAC&R Research 7 (1), 31-49, 2001
362001
Energy use in a district cooling system with stratified chilled-water storage
WP Bahnfleth, WS Joyce
ASHRAE Transactions 100 (1), 1767-1778, 1994
341994
Het systeem kan de bewerking nu niet uitvoeren. Probeer het later opnieuw.
Artikelen 1–20