New in vivo measurements of pressures in the intervertebral disc in daily life HJ Wilke, P Neef, M Caimi, T Hoogland, LE Claes Spine 24 (8), 755-762, 1999 | 2014 | 1999 |
Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants HJ Wilke, K Wenger, L Claes European spine journal 7, 148-154, 1998 | 1021 | 1998 |
Stability Increase of the Lumbar Spine With Different Muscle Groups: A Biomechanical: In: Vitro Study HJ Wilke, S Wolf, LE Claes, M Arand, A Wiesend Spine 20 (2), 192-197, 1995 | 862 | 1995 |
Are animal models useful for studying human disc disorders/degeneration? M Alini, SM Eisenstein, K Ito, C Little, AA Kettler, K Masuda, J Melrose, ... European Spine Journal 17, 2-19, 2008 | 859 | 2008 |
Influence of size and stability of the osteotomy gap on the success of fracture healing L Claes, P Augat, G Suger, HJ Wilke Journal of orthopaedic research 15 (4), 577-584, 1997 | 725 | 1997 |
Intradiscal pressure together with anthropometric data–a data set for the validation of models HJ Wilke, P Neef, B Hinz, H Seidel, L Claes Clinical biomechanics 16, S111-S126, 2001 | 627 | 2001 |
Are sheep spines a valid biomechanical model for human spines? HJ Wilke, A Kettler, LE Claes Spine 22 (20), 2365-2374, 1997 | 566 | 1997 |
Analysis of the influence of disc degeneration on the mechanical behaviour of a lumbar motion segment using the finite element method A Rohlmann, T Zander, H Schmidt, HJ Wilke, G Bergmann Journal of biomechanics 39 (13), 2484-2490, 2006 | 511 | 2006 |
Dynamic stabilization of the lumbar spine and its effects on adjacent segments: an in vitro experiment W Schmoelz, JF Huber, T Nydegger, L Claes, HJ Wilke Clinical Spine Surgery 16 (4), 418-423, 2003 | 508 | 2003 |
Comparison of eight published static finite element models of the intact lumbar spine: predictive power of models improves when combined together M Dreischarf, T Zander, A Shirazi-Adl, CM Puttlitz, CJ Adam, CS Chen, ... Journal of biomechanics 47 (8), 1757-1766, 2014 | 475 | 2014 |
Anatomy of the sheep spine and its comparison to the human spine HJ Wilke, A Kettler, KH Wenger, LE Claes The Anatomical Record: An Official Publication of the American Association …, 1997 | 472 | 1997 |
Application of a new calibration method for a three-dimensional finite element model of a human lumbar annulus fibrosus H Schmidt, F Heuer, U Simon, A Kettler, A Rohlmann, L Claes, HJ Wilke Clinical biomechanics 21 (4), 337-344, 2006 | 455 | 2006 |
Effect of dynamization on gap healing of diaphyseal fractures under external fixation LE Claes, HJ Wilke, P Augat, S Rübenacker, KJ Margevicius Clinical biomechanics 10 (5), 227-234, 1995 | 415* | 1995 |
Posterior Atlantoaxial Fixation: Biomechanical: In Vitro: Comparison of Six Different Techniques M Richter, R Schmidt, L Claes, W Puhl, HJ Wilke Spine 27 (16), 1724-1732, 2002 | 410 | 2002 |
Biomechanical effect of different lumbar interspinous implants on flexibility and intradiscal pressure HJ Wilke, J Drumm, K Haeussler, C Mack, WI Steudel, A Kettler European spine journal 17, 1049-1056, 2008 | 394 | 2008 |
Review of existing grading systems for cervical or lumbar disc and facet joint degeneration A Kettler, HJ Wilke European Spine Journal 15, 705-718, 2006 | 391 | 2006 |
Pedicle screw loosening: a clinically relevant complication? F Galbusera, D Volkheimer, S Reitmaier, N Berger-Roscher, A Kienle, ... European spine journal 24, 1005-1016, 2015 | 387 | 2015 |
Spreader implant for placement between vertebrae E Kast, HJ Wilke, P Weiland US Patent 7,220,280, 2007 | 379 | 2007 |
Intradiscal pressure, shear strain, and fiber strain in the intervertebral disc under combined loading H Schmidt, A Kettler, F Heuer, U Simon, L Claes, HJ Wilke Spine 32 (7), 748-755, 2007 | 371 | 2007 |
A universal spine tester for in vitro experiments with muscle force simulation HJ Wilke, L Claes, H Schmitt, S Wolf European Spine Journal 3, 91-97, 1994 | 368 | 1994 |