Follow
Harki Tanaka
Harki Tanaka
Verified email at ufabc.edu.br
Title
Cited by
Cited by
Year
Imbalances in regional lung ventilation: a validation study on electrical impedance tomography
JA Victorino, JB Borges, VN Okamoto, GFJ Matos, MR Tucci, ...
American journal of respiratory and critical care medicine 169 (7), 791-800, 2004
6592004
Real-time detection of pneumothorax using electrical impedance tomography
ELV Costa, CN Chaves, S Gomes, MA Beraldo, MS Volpe, MR Tucci, ...
Critical care medicine 36 (4), 1230-1238, 2008
1942008
A digital approach for design and fabrication by rapid prototyping of orthosis for developmental dysplasia of the hip
R Munhoz, CAC Moraes, H Tanaka, ME Kunkel
Research on Biomedical Engineering 32, 63-73, 2016
302016
Fuzzy modeling of electrical impedance tomography images of the lungs
H Tanaka, NRS Ortega, MS Galizia, JB Borges, MBP Amato
Clinics 63, 363-370, 2008
282008
Data collection for electrical impedance tomography
H Tanaka
US Patent 8,352,016, 2013
182013
Performance of an Adaptative Multiplexed Current Source used in Electrical Impedance Tomography
P Bertemes Filho, RG Lima, MBP Amato, H Tanaka
XX Brazilian Congress Biomed. Eng, 1167-70, 2006
152006
A Current Source using a Negative Impedance Converter (NIC) for Electrical Impedance Tomography (EIT)
P Bertemes-Filho, RG Lima, H Tanaka
Proceedings of the 17th International Congress on Mechanical Engineering …, 2003
132003
Non-invasive insular stimulation for peripheral neuropathic pain: Influence of target or symptom?
PHM da Cunha, L Dongyang, AM Fernandes, RB Thibes, J Sato, ...
Neurophysiologie Clinique 52 (2), 109-116, 2022
92022
Bedside detection of regional opening/closing pressures by electrical impedance versus computed tomography (CT)
JB Borges, MBP Amato, VN Okamoto, H Tanaka, GF Janot, JA Victorino, ...
American Journal de Respiratory and Critical Care Medicine, A755, 2001
92001
PEEP titration by EIT (Eletric impedance tomography): correlation with multislice CT
MA Beraldo, A Reske, JB Borges, ELV Costas, S Gomes, MS Volpe, ...
Proceedings of the american thoracic society 3, A64, 2006
82006
Parameter estimation of an artificial respiratory system under mechanical ventilation following a noisy regime
V Júnior, M Henrique, LA Forgiarini Junior, TM Kinjo, MBP Amato, ...
Research on Biomedical Engineering 31 (4), 343-351, 2015
72015
Machine Learning e Análise Multivariada aplicados à Sobrevida do Câncer Mama
TS Pinheiro, E Yahata, PD dos Santos, FS de Oliveira, AK Takahata, ...
Journal of Health Informatics 14, 2022
62022
Capacitive-compensated current source used in electrical impedance tomography
P Bertemes-Filho, RG Lima, MBP Amato, H Tanaka
Proc. 12th Int. Conf. Elec. Bioimp. and 5th Conf. Electrical Impedance …, 2004
62004
Modelamento tridimensional de órtese para displasia do desenvolvimento do quadril por fotogrametria
R Munhoz, CAC Moraes, ME Kunkel, H Tanaka
Proceedings of the XXIV Congresso Brasileiro de Engenharia Biomédica, 13-17, 2014
52014
The fast-posterior superior insula (Fast-PSI): A neuronavigation-free targeting method for non-invasive neuromodulation
PHM da Cunha, H Tanaka, JD da Silva Lapa, L Dongyang, AAB Sorte, ...
Brain Stimulation: Basic, Translational, and Clinical Research in …, 2022
42022
Modelling approach to obtain regional respiratory mechanics using electrical impedance tomography and volume-dependent elastance model
M Victor, J Melo, R Roldán, M Nakamura, M Tucci, E Costa, M Amato, ...
Physiological measurement 40 (4), 045001, 2019
42019
Meta-Analysis of the Sensitivity of Decision Support Systems in Diagnosing Diabetic Retinopathy
PW Simões, MG Dos Passos, LL Amaral, D Garcia, RB Vicente, ...
MEDINFO 2019: Health and Wellbeing e-Networks for All, 878-882, 2019
42019
Assessment of mHealth Solutions Applied to Fall Detection for the Elderly.
FS de Oliveira, CC da Silva, TS Pinheiro, LM Yokoi, PD Dos Santos, ...
pHealth, 239-244, 2021
32021
Análise e Mapeamento do Custo de Manutenção de Equipamentos Médicos no Estado de São Paulo
MA Nascimento, H Tanaka
XXIV CONGRESSO BRASILEIRO DE ENGENHARIA BIOMÉDICA, 2014
32014
Estudo da perfusão e ventilação pulmonar em imagens de tomografia de impedância elétrica através de modelagem fuzzy
H Tanaka
Universidade de São Paulo, 2007
32007
The system can't perform the operation now. Try again later.
Articles 1–20