Volgen
Jan Radon
Jan Radon
Universuty of Agriculture in Kraków
Geverifieerd e-mailadres voor ur.krakow.pl
Titel
Geciteerd door
Geciteerd door
Jaar
Experimental measurements and CFD simulation of a ground source heat exchanger operating at a cold climate for a passive house ventilation system
A Flaga-Maryanczyk, J Schnotale, J Radon, K Was
Energy and Buildings 68, 562-570, 2014
912014
Berechnung des hygrothermischen Verhaltens von Räumen
A Holm, J Radon, HM Künzel, K Sedlbauer
452004
Impact of paper and wooden collections on humidity stability and energy consumption in museums and libraries
A Kupczak, A Sadłowska-Sałęga, L Krzemień, J Sobczyk, J Radoń, ...
Energy and Buildings 158, 77-85, 2018
372018
Computational model of heat exchange between dairy cow and bedding
J Radoń, W Bieda, J Lendelová, Š Pogran
Computers and Electronics in Agriculture 107, 29-37, 2014
332014
Experimental study on development of thermal conditions in ground beneath a greenhouse
G Nawalany, W Bieda, J Radoń, P Herbut
Energy and Buildings 69, 103-111, 2014
292014
Coupling of dynamic thermal bridge and whole-building simulation
F Antretter, JR Dring, M Pazold
262013
Integration of Modelica models into an existing simulation software using FMI for Co-Simulation
M Pazold, S Burhenne, J Radon, S Herkel, F Antretter
9th International Modelica Conference, 949-954, 2012
262012
Effect of floor heating and cooling of bedding on thermal conditions in the living area of broiler chickens
G Nawalany, W Bieda, J Radoń
Archiv fur Geflugelkunde 74 (2), 98-101, 2010
222010
Berechnung des hygrothermischen Verhaltens von Räumen-Einfluss des Lüftungsverhaltens auf die Raumluftfeuchte
A Holm, K Sedlbauer, HM Künzel, J Radon
Tagungsbeitrag für das 11, 562-575, 2002
202002
Maintenance of passive house standard in the light of long-term study on energy use in a prefabricated lightweight passive house in central Europe
K Was, J Radon, A Sadłowska-Sałega
Energies 13 (2801), 1-22, 2020
192020
Feasibility and limitation of calculative determination of hygrothermal conditions in historical buildings: Case study of st. Martin church in Wiśniowa
A Sadłowska-Sałęga, J Radoń
Building and Environment 186, 107361, 2020
172020
Influence of selected factors on heat exchange with the ground in a greenhouse
G Nawalany, J Radon, W Bieda, P Sokolowski
Transactions of the ASABE 60 (2), 479-487, 2017
152017
Experimental and theoretical study on hygrothermal long-term performance of outer assemblies in lightweight passive house
J Radon, K Was, A Flaga-Maryanczyk, J Schnotale
Journal of Building Physics 41 (4), 299-320, 2018
142018
Kopplung von dynamischer Wärmebrückenberechnung mit hygrothermischer Gebäudesimulation
F Antretter, M Pazold, J Radon, H Künzel
Bauphysik 35 (3), 181-192, 2013
132013
Problemy cieplno-wilgotnościowe przy renowacji ścian budynków z muru pruskiego
J Radoń, H Künzel
Acta Scientiarum Polonorum: Architectura 5 (1), 45-53, 2006
132006
Uncertainty approaches for hygrothermal building simulations—Drying of AAC in hot and humid climates
AH Holm, HM Kuenzel, J Radon
Buildings VIII Conference, 2002
122002
Integration of HVAC models into a hygrothermal whole building simulation tool
S Burhenne, J Radon, M Pazold, S Herkel, F Antretter
102011
Evaluation of simplified calculation method of heat exchange between building and ground
A Staszczuk, J Radoń, A Holm
Proceedings of the 1st Central European Symposium on Building Physics …, 2010
102010
Critical discussion of a shading calculation method for low energy building and passive house design
M Winkler, F Antretter, J Radon
Energy Procedia 132, 33-38, 2017
92017
Description of the IBP holistic hygrothermal model
A Holm, J Radon, H Künzel, K Sedlbauer
IEA ANNEX 41, 2004
92004
Het systeem kan de bewerking nu niet uitvoeren. Probeer het later opnieuw.
Artikelen 1–20