Follow
Christian Möhler
Christian Möhler
Siemens Healthineers
Verified email at siemens-healthineers.com
Title
Cited by
Cited by
Year
production in collisions at TeV and in collisions at TeV
J Adam, D Adamova, MM Aggarwal, GA Rinella, M Agnello, N Agrawal, ...
Physical Review C 94 (5), 054908, 2016
2242016
Clinical implementation of dual-energy CT for proton treatment planning on pseudo-monoenergetic CT scans
P Wohlfahrt, C Möhler, V Hietschold, S Menkel, S Greilich, M Krause, ...
International Journal of Radiation Oncology* Biology* Physics 97 (2), 427-434, 2017
1372017
Evaluation of stopping-power prediction by dual-and single-energy computed tomography in an anthropomorphic ground-truth phantom
P Wohlfahrt, C Möhler, C Richter, S Greilich
International Journal of Radiation Oncology* Biology* Physics 100 (1), 244-253, 2018
902018
Experimental verification of stopping-power prediction from single-and dual-energy computed tomography in biological tissues
C Möhler, T Russ, P Wohlfahrt, A Elter, A Runz, C Richter, S Greilich
Physics in Medicine & Biology 63 (2), 025001, 2018
862018
Dual-energy CT based proton range prediction in head and pelvic tumor patients
P Wohlfahrt, C Möhler, K Stützer, S Greilich, C Richter
Radiotherapy and Oncology 125 (3), 526-533, 2017
782017
Technical Note: Radiological properties of tissue surrogates used in a multimodality deformable pelvic phantom for MR-guided radiotherapy
NI Niebuhr, W Johnen, T Güldaglar, A Runz, G Echner, P Mann, C Möhler, ...
Medical physics 43 (2), 908-916, 2016
73*2016
Range prediction for tissue mixtures based on dual-energy CT
C Möhler, P Wohlfahrt, C Richter, S Greilich
Physics in Medicine & Biology 61 (11), N268, 2016
682016
Reduction of clinical safety margins in proton therapy enabled by the clinical implementation of dual-energy CT for direct stopping-power prediction
N Peters, P Wohlfahrt, C Hofmann, C Möhler, S Menkel, M Tschiche, ...
Radiotherapy and Oncology 166, 71-78, 2022
572022
Methodological accuracy of image‐based electron‐density assessment using dual‐energy computed tomography
C Möhler, P Wohlfahrt, C Richter, S Greilich
Medical Physics, 0
36
Dual-energy computed tomography to assess intra-and inter-patient tissue variability for proton treatment planning of patients with brain tumor
P Wohlfahrt, C Möhler, EGC Troost, S Greilich, C Richter
International Journal of Radiation Oncology* Biology* Physics 105 (3), 504-513, 2019
292019
Refinement of the Hounsfield look‐up table by retrospective application of patient‐specific direct proton stopping‐power prediction from dual‐energy CT
P Wohlfahrt, C Möhler, W Enghardt, M Krause, D Kunath, S Menkel, ...
Medical Physics 47 (4), 1796-1806, 2020
212020
On the equivalence of image-based dual-energy CT methods for the determination of electron density and effective atomic number in radiotherapy
C Möhler, P Wohlfahrt, C Richter, S Greilich
Physics and Imaging in Radiation Oncology 5, 108-110, 2018
132018
Comment on: Dosimetric comparison of stopping-power calibration with dual-energy CT and single-energy CT in proton therapy treatment planning [Med. Phys. 43 (6), 2845-2854 (2016)].
P Wohlfahrt, C Möhler, S Greilich, C Richter
Medical Physics 44 (10), 5533-5536, 2017
112017
A deep image-to-image network organ segmentation algorithm for radiation treatment planning: Principles and evaluation
S Marschner, M Datar, A Gaasch, Z Xu, S Grbic, G Chabin, B Geiger, ...
Radiation Oncology 17 (1), 129, 2022
92022
Dual-energy CT based assessment of patient-specific range prediction uncertainty in proton treatment planning
W Wohlfahrt, C Möhler, K Stützer, S Greilich, C Richter
Radiother Oncol 125, 526-533, 2017
72017
Clinical validation of Siemens’ Syngo. via automatic contouring system
Ó Pera, Á Martínez, C Möhler, B Hamans, F Vega, F Barral, N Becerra, ...
Advances in Radiation Oncology 8 (3), 101177, 2023
52023
A clinical and time savings evaluation of a deep learning automatic contouring algorithm
JS Ginn, HA Gay, J Hilliard, J Shah, N Mistry, C Möhler, GD Hugo, Y Hao
Medical Dosimetry 48 (1), 55-60, 2023
52023
Dual-energy CT enables dose calculation on scans with iodinated contrast agent
C Möhler, P Wohlfahrt, NH Nicolay, C Richter, S Greilich
Radiotherapy and Oncology, 2018
32018
DirectORGANS 2.0
L Kratzke, N Mistry, C Möhler, A Bruder, S Healthineers, A Müller, ...
3
Towards a generalised development of synthetic CT images and assessment of their dosimetric accuracy
J Handrack, M Bangert, C Möhler, T Bostel, S Greilich
Acta oncologica 59 (2), 180-187, 2020
22020
The system can't perform the operation now. Try again later.
Articles 1–20