Rita Stagni
Rita Stagni
Geverifieerd e-mailadres voor unibo.it
Titel
Geciteerd door
Geciteerd door
Jaar
Quantification of soft tissue artefact in motion analysis by combining 3D fluoroscopy and stereophotogrammetry: a study on two subjects
R Stagni, S Fantozzi, A Cappello, A Leardini
Clinical Biomechanics 20 (3), 320-329, 2005
2862005
Effects of hip joint centre mislocation on gait analysis results
R Stagni, A Leardini, A Cappozzo, MG Benedetti, A Cappello
Journal of biomechanics 33 (11), 1479-1487, 2000
2482000
Mobility of the subtalar joint in the intact ankle complex
A Leardini, R Stagni, JJ O’Connor
Journal of biomechanics 34 (6), 805-809, 2001
1522001
Soft tissue artifact compensation in knee kinematics by double anatomical landmark calibration: performance of a novel method during selected motor tasks
A Cappello, R Stagni, S Fantozzi, A Leardini
IEEE Transactions on biomedical engineering 52 (6), 992-998, 2005
1222005
Estimating fall risk with inertial sensors using gait stability measures that do not require step detection
F Riva, MJP Toebes, M Pijnappels, R Stagni, JH Van Dieën
Gait & posture 38 (2), 170-174, 2013
1162013
Are subject-specific musculoskeletal models robust to the uncertainties in parameter identification?
G Valente, L Pitto, D Testi, A Seth, SL Delp, R Stagni, M Viceconti, ...
PLoS One 9 (11), e112625, 2014
992014
Gait variability and stability measures: Minimum number of strides and within-session reliability
F Riva, MC Bisi, R Stagni
Computers in biology and medicine 50, 9-13, 2014
792014
Role of passive structures in the mobility and stability of the human subtalar joint: a literature review
R Stagni, A Leardini, JJ O'Connor, S Giannini
Foot & ankle international 24 (5), 402-409, 2003
652003
Tendon and ligament fibrillar crimps give rise to left‐handed helices of collagen fibrils in both planar and helical crimps
M Franchi, V Ottani, R Stagni, A Ruggeri
Journal of anatomy 216 (3), 301-309, 2010
642010
Ankle morphometry evaluated using a new semi-automated technique based on X-ray pictures
R Stagni, A Leardini, A Ensini, A Cappello
Clinical biomechanics 20 (3), 307-311, 2005
582005
Double calibration vs. global optimisation: performance and effectiveness for clinical application
R Stagni, S Fantozzi, A Cappello
Gait & posture 29 (1), 119-122, 2009
522009
Measures of gait stability: performance on adults and toddlers at the beginning of independent walking
MC Bisi, F Riva, R Stagni
Journal of neuroengineering and rehabilitation 11 (1), 1-9, 2014
502014
Non-invasive assessment of superficial soft tissue local displacements during movement: a feasibility study
V Camomilla, M Donati, R Stagni, A Cappozzo
Journal of biomechanics 42 (7), 931-937, 2009
432009
Articular contact at the tibiotalar joint in passive flexion
F Corazza, R Stagni, VP Castelli, A Leardini
Journal of biomechanics 38 (6), 1205-1212, 2005
432005
Standardization proposal of soft tissue artefact description for data sharing in human motion measurements
A Cereatti, T Bonci, M Akbarshahi, K Aminian, A Barré, M Begon, ...
Journal of biomechanics 62, 5-13, 2017
422017
Complexity of human gait pattern at different ages assessed using multiscale entropy: from development to decline
MC Bisi, R Stagni
Gait & posture 47, 37-42, 2016
402016
A new semi-automated measurement technique based on X-ray pictures for ankle morphometry
R Stagni, A Leardini, F Catani, A Cappello
Journal of biomechanics 37 (7), 1113-1118, 2004
312004
Analysis of the performance of 17 algorithms from a systematic review: Influence of sensor position, analysed variable and computational approach in gait timing estimation from …
GP Panebianco, MC Bisi, R Stagni, S Fantozzi
Gait & posture 66, 76-82, 2018
302018
Propagation of anatomical landmark misplacement to knee kinematics: performance of single and double calibration
R Stagni, S Fantozzi, A Cappello
Gait & posture 24 (2), 137-141, 2006
282006
Development of gait motor control: what happens after a sudden increase in height during adolescence?
MC Bisi, R Stagni
Biomedical engineering online 15 (1), 47, 2016
272016
Het systeem kan de bewerking nu niet uitvoeren. Probeer het later opnieuw.
Artikelen 1–20