Volgen
Dannis Brouwer
Dannis Brouwer
Professor at the University of Twente
Geverifieerd e-mailadres voor utwente.nl
Titel
Geciteerd door
Geciteerd door
Jaar
Design and modeling of a six DOFs MEMS-based precision manipulator
DM Brouwer, BR De Jong, H Soemers
Precision Engineering 34 (2), 307-319, 2010
752010
An overview of systems for CT‐and MRI‐guided percutaneous needle placement in the thorax and abdomen
MM Arnolli, NC Hanumara, M Franken, DM Brouwer, IAMJ Broeders
The International Journal of Medical Robotics and Computer Assisted Surgery …, 2015
682015
Large deflection stiffness analysis of parallel prismatic leaf-spring flexures
DM Brouwer, JP Meijaard, JB Jonker
Precision engineering 37 (3), 505-521, 2013
642013
Analytical and experimental investigation of a parallel leaf spring guidance
JP Meijaard, DM Brouwer, JB Jonker
Multibody system dynamics 23 (1), 77-97, 2010
552010
A single-mask thermal displacement sensor in MEMS
B Krijnen, RP Hogervorst, JW Van Dijk, JBC Engelen, LA Woldering, ...
Journal of Micromechanics and Microengineering 21 (7), 074007, 2011
402011
Design and performance optimization of large stroke spatial flexures
DH Wiersma, SE Boer, RGKM Aarts, DM Brouwer
Journal of computational and nonlinear dynamics 9 (1), 2014
392014
Building block-based spatial topology synthesis method for large-stroke flexure hinges
M Naves, DM Brouwer, RGKM Aarts
Journal of mechanisms and robotics 9 (4), 041006, 2017
362017
Design and fabrication of a planar three-DOFs MEMS-based manipulator
BR de Jong, DM Brouwer, MJ de Boer, HV Jansen, HMJR Soemers, ...
Journal of microelectromechanical systems 19 (5), 1116-1130, 2010
362010
Flexures for large stroke electrostatic actuation in MEMS
B Krijnen, DM Brouwer
Journal of micromechanics and microengineering 24 (1), 015006, 2013
312013
Long-range elastic guidance mechanisms for electrostatic comb-drive actuators
DM Brouwer, A Otten, JBC Engelen, B Krijnen, H Soemers
Proceedings of the EUSPEN International Conference, 2010
312010
A 2-DOF large stroke flexure based positioning mechanism
KGP Folkersma, SE Boer, DM Brouwer, JL Herder, H Soemers
International Design Engineering Technical Conferences and Computers and …, 2012
26*2012
System for CT‐guided needle placement in the thorax and abdomen: a design for clinical acceptability, applicability and usability
MM Arnolli, M Buijze, M Franken, KP de Jong, DM Brouwer, ...
The International Journal of Medical Robotics and Computer Assisted Surgery …, 2018
252018
UT hand I: A lock-based underactuated hand prosthesis
B Peerdeman, M Valori, D Brouwer, E Hekman, S Misra, S Stramigioli
Mechanism and machine theory 78, 307-323, 2014
242014
A compact McKibben muscle based bending actuator for close-to-body application in assistive wearable robots
M Tschiersky, EEG Hekman, DM Brouwer, JL Herder, K Suzumori
IEEE Robotics and automation letters 5 (2), 3042-3049, 2020
192020
Mechatronic design of the Twente humanoid head
R Reilink, LC Visser, DM Brouwer, R Carloni, S Stramigioli
Intelligent service robotics 4 (2), 107-118, 2011
192011
Design principles for six degrees-of-freedom MEMS-based precision manipulators
DM Brouwer
182007
Multibody modelling and optimization of a curved hinge flexure
SE Boer, R Aarts, DM Brouwer, JB Jonker
The 1st Joint International Conference on Multibody System Dynamics …, 2010
162010
Discrete-amount fluid-dispensing system for a personal care device
JW Grez, GJH Roddeman, JCA Muller, DM Brouwer, F Bremer, ...
US Patent 8,425,133, 2013
152013
Modeling of a flexible instrument to study its sliding behavior inside a curved endoscope
JP Khatait, DM Brouwer, RGKM Aarts, JL Herder
Journal of computational and nonlinear dynamics 8 (3), 2013
142013
Design considerations for a micromachined proportional control valve
MS Groen, DM Brouwer, RJ Wiegerink, JC Lötters
Micromachines 3 (2), 396-412, 2012
142012
Het systeem kan de bewerking nu niet uitvoeren. Probeer het later opnieuw.
Artikelen 1–20