Ventilation, indoor air quality, and health in homes undergoing weatherization PW Francisco, DE Jacobs, L Targos, SL Dixon, J Breysse, W Rose, S Cali Indoor Air 27 (2), 463-477, 2017 | 92 | 2017 |
Measured effect of airflow and refrigerant charge on the seasonal performance of an air-source heat pump using R-410A L Palmiter, JH Kim, B Larson, PW Francisco, EA Groll, JE Braun Energy and buildings 43 (7), 1802-1810, 2011 | 80 | 2011 |
Decomposing the wedge between projected and realized returns in energy efficiency programs P Christensen, P Francisco, E Myers, M Souza Review of Economics and Statistics 105 (4), 798-817, 2023 | 77 | 2023 |
USA CA Francisco Anais do 40th ICOPS, 2007 | 49 | 2007 |
Impacts of weatherization on indoor air quality: A field study of 514 homes S Pigg, D Cautley, PW Francisco Indoor Air 28 (2), 307-317, 2018 | 40 | 2018 |
Unburned methane emissions from residential natural gas appliances Z Merrin, PW Francisco Environmental science & technology 53 (9), 5473-5482, 2019 | 39 | 2019 |
Measured concentrations of combustion gases from the use of unvented gas fireplaces PW Francisco, JR Gordon, B Rose Indoor air 20 (5), 370-379, 2010 | 32 | 2010 |
Measured efficiency of forced-air distribution systems in 24 homes L Palmiter, PW Francisco Proceedings from the, 1994 | 27 | 1994 |
Modeling the thermal distribution efficiency of ducts: comparisons to measured results PW Francisco, L Palmiter, B Davis Energy and Buildings 28 (3), 287-297, 1998 | 24 | 1998 |
Weatherization and indoor air quality: Measured impacts in single-family homes under the weatherization assistance program S Pigg, D Cautley, P Francisco, B Hawkins, T Brennan Oak Ridge National Laboratory, 2014 | 22 | 2014 |
Quantifying proximity, confinement, and interventions in disease outbreaks: a decision support framework for air-transported pathogens TC Bond, A Bosco-Lauth, DK Farmer, PW Francisco, JR Pierce, KM Fedak, ... Environmental science & technology 55 (5), 2890-2898, 2021 | 21 | 2021 |
Heat pump system performance in northern climates PW Francisco, D Baylon, B Davis, L Palmiter TRANSACTIONS-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR CONDITIONING …, 2004 | 21 | 2004 |
Measured heating system efficiency retrofits in eight manufactured (HUD-Code) homes J Siegel, B Davis, P Francisco, L Palmiter Proc. ACEEE Summer Study1998, 2.189-2.201, 1998 | 20 | 1998 |
Field evaluation of the moisture balance technique to characterize indoor wetness WB Rose, PW Francisco 9th International Conference on Thermal Performance of Exterior Envelopes of …, 2004 | 19 | 2004 |
The Nulling Test: A New Measurement Technique of Estimating Duct Leakage in Residential Homes PW Francisco, LS Palmiter TRANSACTIONS-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR CONDITIONING …, 2001 | 17 | 2001 |
Measuring residential duct efficiency with the short-term coheat test methodology PW Francisco, J Siegel, L Palmiter, B Davis Energy and buildings 38 (9), 1076-1083, 2006 | 16 | 2006 |
Insights into improved ways to measure residential duct leakage PW Francisco, L Palmiter, B Davis ASHRAE Transactions 109 (Pt 1), 2003 | 16 | 2003 |
Field evaluation of a new device to measure air handler flow PW Francisco, L Palmiter ASHRAE Transactions 109 (2), 403-412, 2003 | 16 | 2003 |
Infiltration and ventilation measurements on three electrically-heated multifamily buildings P Francisco, L Palmiter Proc. ACEEE Summer Study on Energy Efficiency in Buildings 5, 97-104, 1994 | 16 | 1994 |
Modeled and measured infiltration: Phase II A detailed case study of three homes. L Palmiter, T Bond | 16 | 1993 |