Follow
Mitali Janardan More
Mitali Janardan More
ZOLL Medical Corporation
Verified email at zoll.com
Title
Cited by
Cited by
Year
Optimization of exposure parameters in full field digital mammography
MB Williams, P Raghunathan, MJ More, JA Seibert, A Kwan, JY Lo, ...
Medical physics 35 (6Part1), 2414-2423, 2008
1282008
Optimization of dedicated scintimammography procedure using detector prototypes and compressible phantoms
S Majewski, D Kieper, E Curran, C Keppel, B Kross, A Palumbo, V Popov, ...
IEEE Transactions on Nuclear Science 48 (3), 822-829, 2001
822001
Method and system for image segmentation using models
KS Suryanarayanan, S., Mullick, R., More, M. J
US Patent 8,014,578, 2011
76*2011
Intraoperative imaging guidance for sentinel node biopsy in melanoma using a mobile gamma camera
LT Dengel, MJ More, PG Judy, GR Petroni, ME Smolkin, PK Rehm, ...
Annals of surgery 253 (4), 774-778, 2011
372011
Evaluation of gamma cameras for use in dedicated breast imaging
MJ Moré, PJ Goodale, S Majewski, MB Williams
IEEE transactions on nuclear science 53 (5), 2675-2679, 2006
322006
Evaluation of Gamma Cameras for Use in Dedicated Breast Imaging
MJ More, PJ Goodale, S Majewski, MB Williams
IEEE Transactions on Nuclear Science, 53 (5), 2675 - 2679, 2006
322006
Integrated CT-SPECT system for small-animal imaging
MB Williams, G Zhang, MJ More, AR Goode, S Majewski, RF Wojcik, ...
Penetrating Radiation Systems and Applications II 4142, 265-274, 2000
272000
Analysis of position-dependent Compton scatter in scintimammography with mild compression
MB Williams, D Narayanan, MJ More, PJ Goodale, S Majewski, DA Kieper
Nuclear Science, IEEE Transactions on 50 (5), 1643 - 1649, 2003
222003
Analysis of position-dependent Compton scatter in scintimammography with mild compression
MB Williams, D Narayanan, MJ More, PJ Goodale, S Majewski, D Kieper
2002 IEEE Nuclear Science Symposium Conference Record 2, 863-867, 2002
222002
DIGITALLY ADDRESSED FLAT PANEL X-RAY SOURCES
BC EATON, Mark, Mitali MORE
WO Patent 2,011,044,199, 2011
20*2011
Brain image alignment method and system
MJ Mallya, Y., Suryanarayanan, S., Shriram, K. S
US Patent 8,041,088, 2011
182011
Limited angle dual modality breast imaging
MJ Moré, H Li, PJ Goodale, Y Zheng, S Majewski, V Popov, B Welch, ...
IEEE Transactions on Nuclear Science 54 (3), 504-513, 2007
182007
Limited angle dual modality breast imaging
MJ More, H Li, PJ Goodale, Y Zheng, S Majewski, V Popov, B Welch, ...
Nuclear Science Symposium Conference Record, 2004 IEEE 4, 2407 - 2411, 2004
182004
Optimization of breast imaging procedure with dedicated compact gamma cameras
D Kieper, S Majewski, B Kross, V Popov, AG Weisenberger, B Welch, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2003
172003
Combined structural and functional imaging of the breast
MB Williams, MJ More, D Narayanan, S Majewski, AG Weisenberger, ...
Technology in Cancer Research & Treatment 1 (1), 39-42, 2002
172002
Emerging Technologies in Breast Imaging and Mammography
SL Mitali J. More and Mark B. Williams. Edited by
American Scientific Publishers, 2008
16*2008
X-ray stereotactic lesion localization in conjunction with dedicated scintimammography
MJ More, D Narayanan, PJ Goodale, S Majewski, B Welch, R Wojcik, ...
IEEE Transactions on Nuclear Science 50 (5), 1636-1642, 2003
152003
X-ray stereotactic lesion localization in conjunction with dedicated scintimammography
MJ More, D Narayanan, PJ Goodale, S Majewski, B Welch, R Wojcik, ...
Nuclear Science Symposium Conference Record, 2002 IEEE 2, 1123 - 1127, 2002
152002
New structured scintillators for neutron radiography
VV Nagarkar, EE Ovechkina, HB Bhandari, L Soundara-Pandian, ...
Physics Procedia 69, 161-168, 2015
132015
Phantom study of radiotracer concentration quantification in breast scintigraphy
MB Williams, MJ More, D Narayanan, S Majewski, B Welch, R Wojcik, ...
IEEE Transactions on Nuclear Science 50 (3), 433-438, 2003
132003
The system can't perform the operation now. Try again later.
Articles 1–20