Volgen
Job G Bouwman
Job G Bouwman
PhD candidate
Geverifieerd e-mailadres voor isi.uu.nl
Titel
Geciteerd door
Geciteerd door
Jaar
Alias subtraction more efficient than conventional zero‐padding in the Fourier‐based calculation of the susceptibility induced perturbation of the magnetic field in MR
JG Bouwman, CJG Bakker
Magnetic resonance in medicine 68 (2), 621-630, 2012
412012
Influence of water and fat heterogeneity on fat‐referenced MR thermometry
P Baron, R Deckers, JG Bouwman, CJG Bakker, M de Greef, ...
Magnetic Resonance in Medicine 75 (3), 1187-1197, 2016
362016
Correction of proton resonance frequency shift MR‐thermometry errors caused by heat‐induced magnetic susceptibility changes during high intensity focused ultrasound ablations …
P Baron, R Deckers, M de Greef, LG Merckel, CJG Bakker, JG Bouwman, ...
Magnetic Resonance in Medicine 72 (6), 1580-1589, 2014
362014
Fast Fourier‐based simulation of off‐resonance artifacts in steady‐state gradient echo MRI applied to metal object localization
F Zijlstra, JG Bouwman, I Braškutė, MA Viergever, PR Seevinck
Magnetic resonance in medicine 78 (5), 2035-2041, 2017
302017
Multi-gradient echo MR thermometry for monitoring of the near-field area during MR-guided high intensity focused ultrasound heating
MK Lam, M De Greef, JG Bouwman, CTW Moonen, MA Viergever, ...
Physics in Medicine & Biology 60 (19), 7729, 2015
152015
Geometrically undistorted MRI in the presence of field inhomogeneities using compressed sensing accelerated broadband 3D phase encoded turbo spin-echo imaging
JS Van Gorp, CJG Bakker, JG Bouwman, J Smink, F Zijlstra, PR Seevinck
Physics in Medicine & Biology 60 (2), 615, 2014
122014
Multiple single-point imaging (mSPI) as a tool for capturing and characterizing MR signals and repetitive signal disturbances with high temporal resolution: The MRI scanner as …
CJG Bakker, JS van Gorp, JL Verwoerd, AH Westra, JG Bouwman, ...
Magnetic Resonance Imaging 31 (7), 1037-1043, 2013
72013
On the utility of spectroscopic imaging as a tool for generating geometrically accurate MR images and parameter maps in the presence of field inhomogeneities and chemical shift …
CJG Bakker, H de Leeuw, GH van de Maat, JS van Gorp, JG Bouwman, ...
Magnetic Resonance Imaging 31 (1), 86-95, 2013
62013
Multispectral 3D phase-encoded turbo spin-echo for imaging near metal: Limitations and possibilities demonstrated by simulations and phantom experiments
JS van Gorp, R Nizak, JG Bouwman, DBF Saris, PR Seevinck
Magnetic resonance imaging 39, 31-43, 2017
32017
Fully automatic in-vivo localization of LDR brachytherapy seeds for post-implant dosimetry using MR simulations and template matching
F Zijlstra, JG Bouwman, MA Moerland, PR Seevinck
Proceedings of the 24th Annual Meeting of ISMRM, Singapore 3615, 2016
32016
Localization of an HDR brachytherapy source using MR artifact simulation and phase-only cross correlation
E Beld, MA Moerland, JG Bouwman, F Zijlstra, JJW Lagendijk, ...
Proceedings of the 23rd Annual Meeting of the ISMRM, 2015
22015
Geometrically undistorted imaging of orthopedic implants using compressed sensing accelerated phase encoded imaging
JS van Gorp, CJG Bakker, F Zijlstra, J Smink, JG Bouwman, PR Seevinck
Proceedings of the 22nd Annual Meeting of ISMRM, Milan, Italy, 1680, 2014
22014
Towards compressed sensing accelerated geometrically undistorted single point images under 10 seconds
JS Van Gorp, JG Bouwman, CJG Bakker, PR Seevinck
Proc Intl Soc Magn Reson Med 20, 1599, 2012
22012
Fast simulation of off-resonance artifacts in MRI using FORECAST (Fourier-based Off-REsonanCe Artifact Simulation in the STeady-State)
F Zijlstra, JG Bouwman, I Braškute, PR Seevinck
Proceedings of the 24th Annual Meeting of ISMRM, Singapore 1936, 2016
12016
Compressed sensing accelerated broadband 3D phase encoded turbo spin-echo imaging for geometrically undistorted imaging in the presence of field inhomogeneities
J van Gorp, C Bakker, J Bouwman, J Smink, F Zijlstra, P Seevinck
Proceedings of the 23rd Annual Meeting of the ISMRM, 2015
12015
Influence of magnetic susceptibility on absolute temperature as measured directly from the water/fat frequency shift.
P Baron, M De Greef, R Deckers, CJG Bakker, JG Bouwman, LW Bartels
Proceedings of the 23rd Annual Meeting of ISMRM, Milan, Italy, 3678, 2014
12014
Compressed sensing-accelerated spectroscopic imaging to obtain geometrically accurate water-fat images and field maps for use in MR-guided interventions.
JS Van Gorp, SPM Crijns, JG Bouwman, BW Raaymakers, CJG Bakker, ...
Proc 20th Annual Meeting ISMRM (Melbourne) 202, 2012
12012
Towards realtime 4D field shift predictions: Optimizing Fourier-based calculations of the susceptibility induced perturbation of the magnetic field.
JG Bouwman, JS van Gorp, PR Seevinck, CJG Bakker
Proceedings of the 20th Annual Meeting of ISMRM, Melbourne, Australia, 278, 2012
12012
isoPhasor: a generic and precise marker visualization, localization, and quantification method based on phase saddles in 3D MR imaging
JG Bouwman, BA Custers, CJG Bakker, MA Viergever, PR Seevinck
Magnetic Resonance in Medicine 81 (3), 2038-2051, 2019
2019
QSM: fast selection of optimal regularization weights
JG Bouwman, PR Seevinck
Proc. Intl. Soc. Mag. Reson. Med 24, 1561, 2016
2016
Het systeem kan de bewerking nu niet uitvoeren. Probeer het later opnieuw.
Artikelen 1–20