Follow
Jeffrey L Lacy
Jeffrey L Lacy
President Proportional Technologies, Inc
Verified email at proportionaltech.com - Homepage
Title
Cited by
Cited by
Year
Evidence for the existence of cosmic-ray antiprotons
RL Golden, S Horan, BG Mauger, GD Badhwar, JL Lacy, SA Stephens, ...
Physical Review Letters 43 (16), 1196, 1979
4311979
A measurement of the absolute flux of cosmic-ray electrons
RL Golden, BG Mauger, GD Badhwar, RR Daniel, JL Lacy, SA Stephens, ...
Astrophysical Journal, Part 1 (ISSN 0004-637X), vol. 287, Dec. 15, 1984, p …, 1984
1341984
Observation of cosmic ray positrons in the region from 5 to 50 GeV
RL Golden, BG Mauger, S Horan, SA Stephens, RR Daniel, GD Badhwar, ...
Astronomy and Astrophysics (ISSN 0004-6361), vol. 188, no. 1, Dec. 1987, p …, 1987
1211987
Performance of a 62Zn/62Cu generator in clinical trials of PET perfusion agent 62Cu-PTSM
NG Haynes, JL Lacy, N Nayak, CS Martin, D Dai, CJ Mathias, MA Green
Journal of Nuclear Medicine 41 (2), 309-314, 2000
1052000
Boron-coated straws as a replacement for 3He-based neutron detectors
JL Lacy, A Athanasiades, L Sun, CS Martin, TD Lyons, MA Foss, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2011
912011
Relative abundance of antiprotons and antihelium in the primary cosmic radiation
GD Badhwar, RL Golden, JL Lacy, JE Zipse, RR Daniel, SA Stephens
Nature 274 (5667), 137-139, 1978
761978
A magnetic spectrometer for cosmic ray studies
RL Golden, GD Badhwar, JL Lacy, JE Zipse
Nuclear Instruments and Methods 148 (1), 179-185, 1978
691978
High-resolution readout of multiwire proportional counters using the cathode-coupled delay-line technique
JL Lacy, RS Lindsey
Nuclear Instruments and Methods 119, 483-498, 1974
651974
PET of Hypoxia and Perfusion with 62Cu-ATSM and 62Cu-PTSM Using a 62Zn/62Cu Generator
TZ Wong, JL Lacy, NA Petry, TC Hawk, TA Sporn, MW Dewhirst, ...
American Journal of Roentgenology 190 (2), 427-432, 2008
622008
Assessment of Cu-ETS as a PET radiopharmaceutical for evaluation of regional renal perfusion
MA Green, CJ Mathias, LR Willis, RK Handa, JL Lacy, MA Miller, ...
Nuclear medicine and biology 34 (3), 247-255, 2007
622007
Validation of left ventricular volume measurements by radionuclide angiography
MS Verani, J Gaeta, AD LeBlanc, LR Poliner, LA Phillips, JL Lacy, ...
Journal of nuclear medicine 26 (12), 1394-1401, 1985
611985
Boron coated straw neutron detector
JL Lacy
US Patent 7,002,159, 2006
552006
Human biodistribution and dosimetry of the PET perfusion agent copper-62-PTSM
TR Wallhaus, J Lacy, J Whang, MA Green, RJ Nickles, CK Stone
Journal of Nuclear Medicine 39 (11), 1958-1964, 1998
531998
Straw detector for high rate, high resolution neutron imaging
A Athanasiades, NN Shehad, CS Martin, L Sun, JL Lacy
IEEE Nuclear Science Symposium Conference Record, 2005 2, 623-627, 2005
492005
Quantification of left ventricular performance during transient coronary occlusion at various anatomic sites in humans: a study using tantalum-178 and a multiwire gamma camera
MS Verani, JL Lacy, GW Guidry, S Nishimura, JJ Mahmarian, ...
Journal of the American College of Cardiology 19 (2), 297-306, 1992
491992
Cosmic ray antiproton and positron production in the interstellar medium
GD Badhwar, RL Golden, ML Brown, JL Lacy
Astrophysics and Space Science 37, 283-300, 1975
471975
A gamma camera for medical applications, using a multiwire proportional counter
JL Lacy, AD LeBlanc, JW Babich, MW Bungo, LA Latson, RM Lewis, ...
Journal of nuclear medicine 25 (9), 1003-1012, 1984
421984
Copper-62-pyruvaldehyde bis (N4-methyl-thiosemicarbazone) PET imaging in the detection of coronary artery disease in humans
TR Wallhaus, J Lacy, R Stewart, J Bianco, MA Green, N Nayak, CK Stone
Journal of Nuclear Cardiology 8 (1), 67-74, 2001
402001
High speed multiwire photon camera
JL Lacy
US Patent 4,999,501, 1991
401991
First-pass radionuclide angiography using a multiwire gamma camera and tantalum-178
JL Lacy, MS Verani, ME Ball, TM Boyce, RW Gibson, R Roberts
Journal of nuclear medicine 29 (3), 293-301, 1988
381988
The system can't perform the operation now. Try again later.
Articles 1–20