Bart Kaptein
Bart Kaptein
Senior researcher Dept. of Orthopaedics, Leiden University Medical Center
Verified email at lumc.nl
Title
Cited by
Cited by
Year
A new model-based RSA method validated using CAD models and models from reversed engineering
BL Kaptein, ER Valstar, BC Stoel, PM Rozing, JHC Reiber
Journal of biomechanics 36 (6), 873-882, 2003
2462003
2D–3D shape reconstruction of the distal femur from stereo X-ray imaging using statistical shape models
N Baka, BL Kaptein, M de Bruijne, T van Walsum, JE Giphart, WJ Niessen, ...
Medical image analysis 15 (6), 840-850, 2011
1582011
Soft-tissue artefact assessment during step-up using fluoroscopy and skin-mounted markers
EH Garling, BL Kaptein, B Mertens, W Barendregt, HEJ Veeger, ...
Journal of biomechanics 40, S18-S24, 2007
1142007
Clinical validation of model-based RSA for a total knee prosthesis
BL Kaptein, ER Valstar, BC Stoel, HC Reiber, RG Nelissen
Clinical Orthopaedics and Related Research® 464, 205-209, 2007
1012007
Development and experimental validation of a three-dimensional finite element model of the human scapula
S Gupta, FCT Van Der Helm, JC Sterk, F Van Keulen, BL Kaptein
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2004
972004
Marker configuration model-based roentgen fluoroscopic analysis
EH Garling, BL Kaptein, K Geleijns, RGHH Nelissen, ER Valstar
Journal of biomechanics 38 (4), 893-901, 2005
872005
Good diagnostic performance of early migration as a predictor of late aseptic loosening of acetabular cups: results from ten years of follow-up with Roentgen …
MJ Nieuwenhuijse, ER Valstar, BL Kaptein, RGHH Nelissen
JBJS 94 (10), 874-880, 2012
752012
Model-based RSA of a femoral hip stem using surface and geometrical shape models
BL Kaptein, ER Valstar, CW Spoor, BC Stoel, PM Rozing
Clinical Orthopaedics and Related Research® 448, 92-97, 2006
682006
Cemented versus cementless Oxford unicompartmental knee arthroplasty using radiostereometric analysis: A randomised controlled trial
BJL Kendrick, BL Kaptein, ER Valstar, HS Gill, WFM Jackson, CAF Dodd, ...
The bone & joint journal 97 (2), 185-191, 2015
672015
Evaluation of three pose estimation algorithms for model-based roentgen stereophotogrammetric analysis
BL Kaptein, E R Valstar, BC Stoel, PM Rozing, JHC Reiber
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2004
672004
Polyethylene wear of mobile-bearing unicompartmental knee replacement at 20 years
BJL Kendrick, DJ Simpson, BL Kaptein, ER Valstar, HS Gill, DW Murray, ...
The Journal of bone and joint surgery. British volume 93 (4), 470-475, 2011
632011
Comparison of the model-based and marker-based roentgen stereophotogrammetry methods in a typical clinical setting
C Hurschler, F Seehaus, J Emmerich, BL Kaptein, H Windhagen
The Journal of arthroplasty 24 (4), 594-606, 2009
612009
Image-based RSA: Roentgen stereophotogrammetric analysis based on 2D–3D image registration
PW De Bruin, BL Kaptein, BC Stoel, JHC Reiber, PM Rozing, ER Valstar
Journal of biomechanics 41 (1), 155-164, 2008
532008
The Exeter femoral stem continues to migrate during its first decade after implantation: 10–12 years of follow-up with radiostereometric analysis (RSA)
MJ Nieuwenhuijse, ER Valstar, BL Kaptein, RGHH Nelissen
Acta orthopaedica 83 (2), 129-134, 2012
462012
Limited rotation of the mobile-bearing in a rotating platform total knee prosthesis
EH Garling, BL Kaptein, RGHH Nelissen, ER Valstar
Journal of biomechanics 40, S25-S30, 2007
462007
Estimating muscle attachment contours by transforming geometrical bone models
BL Kaptein, FCT Van der Helm
Journal of biomechanics 37 (3), 263-273, 2004
462004
A comparison of calibration methods for stereo fluoroscopic imaging systems
BL Kaptein, KB Shelburne, MR Torry, JE Giphart
Journal of biomechanics 44 (13), 2511-2515, 2011
412011
A new type of model-based Roentgen stereophotogrammetric analysis for solving the occluded marker problem
BL Kaptein, ER Valstar, BC Stoel, PM Rozing, JHC Reiber
Journal of biomechanics 38 (11), 2330-2334, 2005
402005
Differences in long-term fixation between mobile-bearing and fixed-bearing knee prostheses at ten to 12 years’ follow-up: a single-blinded randomised controlled …
BG Pijls, ER Valstar, BL Kaptein, R Nelissen
The Journal of bone and joint surgery. British volume 94 (10), 1366-1371, 2012
382012
Evaluation of automated statistical shape model based knee kinematics from biplane fluoroscopy
N Baka, BL Kaptein, JE Giphart, M Staring, M de Bruijne, BPF Lelieveldt, ...
Journal of biomechanics 47 (1), 122-129, 2014
372014
The system can't perform the operation now. Try again later.
Articles 1–20