Volgen
Achilles Karagiozis
Achilles Karagiozis
Buildings Thermal Science Center Director, NREL
Geverifieerd e-mailadres voor nrel.gov
Titel
Geciteerd door
Geciteerd door
Jaar
Simulation of indoor temperature and humidity conditions including hygrothermal interactions with the building envelope
HM Künzel, A Holm, D Zirkelbach, AN Karagiozis
Solar energy 78 (4), 554-561, 2005
1992005
Wind-driven rain distributions on two buildings
A Karagiozis, G Hadjisophocleous, S Cao
Journal of Wind Engineering and Industrial Aerodynamics 67, 559-572, 1997
831997
Hygrothermal system-performance of a whole building
A Karagiozis, M Salonvaara
Building and Environment 36 (6), 779-787, 2001
782001
Moisture buffering effects on indoor air quality-experimental and simulation results
M Salonvaara, T Ojanen, A Holm, HM Künzel, AN Karagiozis
Proceedings (CD) of the Performance of Exterior Envelopes of Whole Buildings …, 2004
732004
WUFI-ORNL/IBP—a North American hygrothermal model
A Karagiozis, H Künzel, A Holm
Performance of Exterior Envelopes of Whole Buildings VIII, 2-7, 2001
672001
Air Cavities Behind Claddings—What Have We Learned?
M Salonvarra, AN Karagiozis, M Pazera, W Miller
Thermal Performance of the Exterior Envelopes of Whole Buildings Tenth …, 2007
552007
Stochastic building envelope modeling—the influence of material properties
M Salonvaara, A Karagiozis, A Holm
Thermal Performance of Exterior Envelopes of Whole Buildings VIII, 2-8, 2001
532001
Moisture transport in building envelopes using an approximate factorization solution method
M Salonvaara, A Karagiozis
CFD Society of Canada, Toronto, June, 1-3, 1994
511994
Natural convection heat transfer from arrays of isothermal triangular fins in air
A Karagiozis, GD Raithby, KGT Hollands
491994
Temperature distribution in a slab during hot rolling
AN Karagiozis, JG Lenard
The American Society of Mechanical Engineers (ASME), 1988
451988
Overview of the 2-D hygrothermal heat-moisture transport model LATENITE
A Karagiozis
Internal IRC/BPL Report, 1993
421993
The effect of air cavity convection on the wetting and drying behavior of wood-frame walls using a multi-physics approach
AN Karagiozis, HM Kuenzel
ASTM International 6 (10), JAI101455, 2009
392009
Computer model calculations on the performance of vapor barriers in canadian residential buildings.
AN Karagiozis, MK Kumaran
391993
Barrier EIFS clad walls: results from a moisture engineering study
W Brown, J Ullett, A Karagiozis, T Tonyan
Journal of Thermal Insulation and Building Envelopes 20 (3), 206-226, 1997
381997
Airflow in the ventilation space behind a rain screen wall
TK Stovall, AN Karagiozis
Exterior Envelopes of Whole Buildings Ninth International Conference, 2004
352004
Review of in-service moisture and temperature conditions in wood-frame buildings
SV Glass, A TenWolde
General Technical Report FPL-GTR-174. Madison, WI: US Department of …, 2007
332007
Measurements and two-dimensional computer simulations of the hygrothermal performance of a wood frame wall
S Geving, A Karagiozis, M Salonvaara
Journal of Thermal Insulation and Building Envelopes 20 (4), 301-319, 1997
271997
The effect of material properties on the coefficient of friction in cold rolling
AN Karagiozis, JG Lenard
Proc. Eurotrib 85, 2-13, 1985
261985
Influence of wind-driven rain data on hygrothermal performance
AN Karagiozis, M Salonvaara, A Holm, H Kuenzel
Proceedings of the eighth international IBPSA conference, Eindhoven, the …, 2003
252003
Assessing the benefits of cavity ventilation by hygrothermal simulation
HM Künzel, AN Karagiozis, M Kehrer
Building physics symposium in honour of Prof. Hugo LSC Hens. Leuven, Belgium, 2008
242008
Het systeem kan de bewerking nu niet uitvoeren. Probeer het later opnieuw.
Artikelen 1–20