Craig H. Meyer
Craig H. Meyer
Professor of Biomedical Engineering and Radiology, University of Virginia
Verified email at virginia.edu - Homepage
Title
Cited by
Cited by
Year
Selection of a convolution function for Fourier inversion using gridding (computerised tomography application)
JI Jackson, CH Meyer, DG Nishimura, A Macovski
IEEE transactions on medical imaging 10 (3), 473-478, 1991
13911991
Fast spiral coronary artery imaging
CH Meyer, BS Hu, DG Nishimura, A Macovski
Magnetic resonance in medicine 28 (2), 202-213, 1992
11211992
Identifying the best machine learning algorithms for brain tumor segmentation, progression assessment, and overall survival prediction in the BRATS challenge
S Bakas, M Reyes, A Jakab, S Bauer, M Rempfler, A Crimi, RT Shinohara, ...
arXiv preprint arXiv:1811.02629, 2018
6752018
Simultaneous spatial and spectral selective excitation
CH Meyer, JM Pauly, A Macovskiand, DG Nishimura
Magnetic resonance in medicine 15 (2), 287-304, 1990
6271990
Coronary Angiography with Magnetization‐Prepared T2 Contrast
JH Brittain, BS Hu, GA Wright, CH Meyer, A Macovski, DG Nishimura
Magnetic resonance in medicine 33 (5), 689-696, 1995
4761995
Discrimination of large venous vessels in time‐course spiral blood‐oxygen‐level‐dependent magnetic‐resonance functional neuroimaging
AT Lee, GH Glover, CH Meyer
Magnetic resonance in medicine 33 (6), 745-754, 1995
3981995
A homogeneity correction method for magnetic resonance imaging with time-varying gradients
DC Noll, CH Meyer, JM Pauly, DG Nishimura, A Macovski
IEEE transactions on medical imaging 10 (4), 629-637, 1991
3361991
Technology insight: in vivo cell tracking by use of MRI
WJ Rogers, CH Meyer, CM Kramer
Nature Clinical Practice Cardiovascular Medicine 3 (10), 554-562, 2006
3172006
Spiral K‐space MR imaging of cortical activation
DC Noll, JD Cohen, CH Meyer, W Schneider
Journal of Magnetic Resonance Imaging 5 (1), 49-56, 1995
3091995
The upper limit of human smooth pursuit velocity
CH Meyer, AG Lasker, DA Robinson
Vision research 25 (4), 561-563, 1985
2911985
Deblurring for non‐2D Fourier transform magnetic resonance imaging
DC Noll, JM Pauly, CH Meyer, DG Nishimura, A Macovskj
Magnetic Resonance in Medicine 25 (2), 319-333, 1992
2811992
Real‐time interactive MRI on a conventional scanner
AB Kerr, JM Pauly, BS Hu, KC Li, CJ Hardy, CH Meyer, A Macovski, ...
Magnetic resonance in medicine 38 (3), 355-367, 1997
2781997
Volumetric spectroscopic imaging with spiral‐based k‐space trajectories
E Adalsteinsson, P Irarrazabal, S Topp, C Meyer, A Macovski, ...
Magnetic resonance in medicine 39 (6), 889-898, 1998
2721998
Real‐time motion detection in spiral MRI using navigators
TS Sachs, CH Meyer, BS Hu, J Kohli, DG Nishimura, A Macovski
Magnetic resonance in medicine 32 (5), 639-645, 1994
2601994
Inhomogeneity correction using an estimated linear field map
P Irarrazabal, CH Meyer, DG Nishimura, A Macovski
Magnetic resonance in medicine 35 (2), 278-282, 1996
2201996
A Velocity k‐Space Analysis of Flow Effects in Echo‐Planar and Spiral Imaging
DG Nishimura, P Irarrazabal, CH Meyer
Magnetic resonance in medicine 33 (4), 549-556, 1995
2081995
The diminishing variance algorithm for real‐time reduction of motion artifacts in MRI
TS Sachs, CH Meyer, P Irarrazabal, BS Hu, DG Nishimura, A Macovski
Magnetic resonance in medicine 34 (3), 412-422, 1995
1961995
Relationships of 35 lower limb muscles to height and body mass quantified using MRI
GG Handsfield, CH Meyer, JM Hart, MF Abel, SS Blemker
Journal of biomechanics 47 (3), 631-638, 2014
1932014
Magnetic resonance fluoroscopy using spirals with variable sampling densities
DM Spielman, JM Pauly, CH Meyer
Magnetic resonance in medicine 34 (3), 388-394, 1995
1731995
Imaging three‐dimensional myocardial mechanics using navigator‐gated volumetric spiral cine DENSE MRI
X Zhong, BS Spottiswoode, CH Meyer, CM Kramer, FH Epstein
Magnetic resonance in medicine 64 (4), 1089-1097, 2010
1632010
The system can't perform the operation now. Try again later.
Articles 1–20