Just Herder
Just Herder
Geverifieerd e-mailadres voor tudelft.nl - Homepage
Titel
Geciteerd door
Geciteerd door
Jaar
Bistable vibration energy harvesters: a review
SP Pellegrini, N Tolou, M Schenk, JL Herder
Journal of Intelligent Material Systems and Structures 24 (11), 1303-1312, 2013
3312013
Energy-free Systems. Theory, conception and design of statically
JL Herder
a a 2, 1, 2001
2582001
Sensitivity of laparoscopic dissectors
KT Den Boer, JL Herder, W Sjoerdsma, DW Meijer, DJ Gouma, ...
Surgical Endoscopy 13 (9), 869-873, 1999
971999
Non-invasive control interfaces for intention detection in active movement-assistive devices
J Lobo-Prat, PN Kooren, AHA Stienen, JL Herder, BFJM Koopman, ...
Journal of neuroengineering and rehabilitation 11 (1), 168, 2014
952014
Force-directed design of a voluntary closing hand prosthesis
H De Visser, JL Herder
JRRD: Journal of Rehabilitation Research and Development, 37 (3), 2000, 2000
942000
Principle and design of a mobile arm support for people with muscular weakness
JL Herder, N Vrijlandt, T Antonides, M Cloosterman, PL Mastenbroek
Journal of rehabilitation research and development 43 (5), 591, 2006
922006
Comparison of various dynamic balancing principles regarding additional mass and additional inertia
V van der Wijk, JL Herder, B Demeulenaere
Journal of mechanisms and robotics 1 (4), 2009
912009
Forces and displacements in colon surgery
H Visser, EAM Heijnsdijk, JL Herder, PV Pistecky
Surgical Endoscopy And Other Interventional Techniques 16 (10), 14263-1430, 2002
912002
Spring-to-spring balancing as energy-free adjustment method in gravity equilibrators
R Barents, M Schenk, WD van Dorsser, BM Wisse, JL Herder
Journal of Mechanical Design 133 (6), 2011
862011
Force transmission of laparoscopic grasping instruments
W Sjoerdsma, JL Herder, MJ Horward, A Jansen, JJG Bannenberg, ...
Minimally Invasive Therapy & Allied Technologies 6 (4), 274-278, 1997
861997
Design, actuation and control of an anthropomorphic robot arm
GJM Tuijthof, JL Herder
Mechanism and machine theory 35 (7), 945-962, 2000
852000
Zero stiffness tensegrity structures
M Schenk, SD Guest, JL Herder
International Journal of Solids and Structures 44 (20), 6569-6583, 2007
832007
Design of spring force compensation systems
JL Herder
Mechanism and machine theory 33 (1-2), 151-161, 1998
821998
The ability of underactuated hands to grasp and hold objects
GA Kragten, JL Herder
Mechanism and Machine Theory 45 (3), 408-425, 2010
802010
Development of a statically balanced arm support: ARMON
JL Herder
9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005 …, 2005
762005
Camera and instrument holders and their clinical value in minimally invasive surgery
JEN Jaspers, P Breedveld, JL Herder, CA Grimbergen
Surgical Laparoscopy Endoscopy & Percutaneous Techniques 14 (3), 145-152, 2004
692004
Statically balanced compliant mechanisms (SBCM’s), an example and prospects
JL Herder, FPA Van Den Berg
Proceedings of the 26th ASME DETC biennial, mechanisms and robotics conference, 2000
602000
Design of a generic zero stiffness compliant joint
FM Morsch, JL Herder
International Design Engineering Technical Conferences and Computers and …, 2010
552010
Conceptual design of a passive arm orthosis
LF Cardoso, S Toma´ zio, JL Herder
International Design Engineering Technical Conferences and Computers and …, 2002
552002
Design and experimental evaluation of a dynamically balanced redundant planar 4-RRR parallel manipulator
V Van Der Wijk, S Krut, F Pierrot, JL Herder
The International Journal of Robotics Research 32 (6), 744-759, 2013
542013
Het systeem kan de bewerking nu niet uitvoeren. Probeer het later opnieuw.
Artikelen 1–20