A new method in gamma-ray spectroscopy: A two crystal scintillation spectrometer with improved resolution

AM Hoogenboom - Nuclear Instruments, 1958 - Elsevier
A new method has been developed to measure the spectra of gamma radiation emitted in
cascade disintegrations. Use is made of a two-crystal scintillation spectrometer and a gated …

Thermal analysis of bismuth germanate compounds

G Corsmit, MA Van Driel, RJ Elsenaar… - Journal of crystal …, 1986 - Elsevier
A new measurement of the stable and metastable phase diagrams of the binary mixture Bi 2
O 3 /GeO 2 is reported. It is found that for any composition between (25% Bi 2 O 3 , 75% …

Polarization measurements of proton capture gamma rays

M Suffert, PM Endt, AM Hoogenboom - Physica, 1959 - Elsevier
The linear polarization has been measured of eight different gamma rays of widely differing
energies (E γ = 0.8 - 8.0 MeV) emitted at resonances in the 24 Mg(p, γ) 25 Al, 30 Si(p, γ ) 31 P…

Stripping Analysis of the () Angular Distributions from the and the Reactions

AM Hoogenboom, E Kashy, WW Buechner - Physical Review, 1962 - APS
The analysis of the angular distribution of the protons from the Cl 3 5, 3 7 (d, p) Cl 3 6, 3 8
reactions revealed forty-six levels in Cl 36 and four levels in Cl 38, previously unreported, and …

Level Structure of from the Reaction

E Kashy, AM Hoogenboom, WW Buechner - Physical Review, 1961 - APS
The energy-level structure of Ar 41 has been investigated by bombarding argon gas with 7.5-Mev
deuterons and measuring the energy spectrum and angular distributions of the …

Nuclear Energy Levels in

MW Brenner, AM Hoogenboom, E Kashy - Physical Review, 1962 - APS
Excited levels in P 29 have been observed as resonances in the differential elastic and
inelastic scattering cross sections for protons incident upon natural silicon (92.2% Si 28) at …

A data acquisition system with mass storage

PBJ Van Elswijk, R Engmann, AM Hoogenboom… - Nuclear Instruments and …, 1971 - Elsevier
A data handling system consisting of a small computer with disk storage and magnetic tape
has been developed for various kinds of nuclear spectroscopy experiments. The operator …

Gas Target for the Multiple‐Gap, Broad‐Range Spectrograph

AM Hoogenboom - Review of Scientific Instruments, 1961 - pubs.aip.org
A gas target with a very thin cylindrical window has been developed for use with the new
MIT multiple‐gap, broad‐range spectrograph. This gas target permits observation of reaction …

On the Decay of 106Rh

OJ Segaert, J Demuynck, AM Hoogenboom… - Nuclear Physics, 1960 - Elsevier
The beta and gamma radiation following the 30 sec decay of 100 Rh has been investigated
with a double-focusing beta-ray spectrometer, single-crystal, coincidence and sum-…

The injector of the Utrecht en tandem

K van der Borg, AP de Haas, AM Hoogenboom… - Nuclear Instruments and …, 1984 - Elsevier
An injector has been built to obtain improved beam transmission through the EN tandem.
The injector has been provided with a 90 analysing magnet, m/Δm = 300, and 130 kV …